Spectrum preview
Title
Optical constants of FeS in MIR/FIR
Database
Experiment type
laboratory measurement
Spectrum type
optical constants
Version
#1 (2021-02-19 10:14:17 UTC+0000)
Instrument parameters
Instrument
BRUKER 113v – reflection Mid-IR
Spectral observation mode
spectrum
Valid spectral range(s)
2.0 - 25.0 ${\mu}m$
Observation geometry
specular : i=12.0° ; e=12.0°
Angle observation mode
fixed angles
Spatial observation mode
single spot
Instrument parameters
Instrument
BRUKER 113v – reflection Far-IR with bolometer detector
Spectral observation mode
spectrum
Valid spectral range(s)
15.0 - 500.0 ${\mu}m$
Observation geometry
specular : i=12.0° ; e=12.0°
Angle observation mode
fixed angles
Spatial observation mode
single spot
Sample preview
Name
FeS
Origin
laboratory
Texture
compact
Thickness
1.0 $mm$
Temperature
300.0 $\pm$ 5.0 $K$
References
Data reference