Cu K edge XAS transmission of Cu metallic reference foil at ambient conditions
- Title
- Cu K edge XAS transmission of Cu metallic reference foil at ambient conditions
- DOI
- 10.26302/SSHADE/EXPERIMENT_DT_20180117_002
- Data reference
- Proux, Olivier (2008): Cu K edge XAS transmission of Cu metallic foil reference at ambient conditions. SSHADE/FAME (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_DT_20180117_002
- Database
- Experimentalists
- Experiment type
- laboratory measurement
- Type
- transmission
- Intensity unit
- AU
- Standard medium
- unknown
- Observation mode
- spectrum
- Spectral range type(s)
- hard X
- Valid spectral range(s)
-
Min - Max (eV) Sampling (eV) Resolution (eV) Position accuracy (eV) Absorption edge #1 8850.0 - 9832.0 0.46 Cu (K: 8.9878 keV) - Comments
- The resolution in the above table is the resolution given by the monochromator. The energy was calibrated on the spectrum itself: by definition, th first maximum of the derivative was set at 8979 eV.
- Observation mode
- single spot
- Name
- Cu metallic foil
- Experiment
- Cu K edge XAS transmission of Cu metallic foil reference at ambient conditions
- Date begin
- 2008-06-10
- Release date
- 2018-01-31 23:51:01+0000 UTC
- Version (Date)
- #1 (2018-01-31 23:51:01+0000 UTC)
- History
-
Date Mode Version Status Comments 2018-01-17 14:44:11+0000 UTC first import #1 valid version First import
- Analysis
- raw averaged spectra
- Quality flag
- 3