- DOI
- 10.26302/SSHADE/EXPERIMENT_IK_20181029_001
- Data reference
- Kieffer, Isabelle (2018): Pb L3 edge XAS transmission of Pb metallic foil reference at ambient conditions. SSHADE/FAME (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_IK_20181029_001
- Database(s)
- Experimentalists
- Type(s)
- laboratory measurement
- Number of spectra
- 1
- Variable type(s)
-
- no
- Standard medium
- unknown
- Observation mode
- spectrum
- Spectral range type(s)
- hard X
- Valid spectral range(s)
-
Min - Max ($eV$) Sampling ($eV$) Resolution ($eV$) Position accuracy ($eV$) Absorption edge #1 12848.0 - 13493.0 0.67 $Pb$ (L3: 13.0352 $keV$) - Comments
- The resolution in the above table is the resolution given by the monochromator. The energy was calibrated on the spectrum itself: by definition, th first maximum of the derivative was set at 13035 eV.
- Observation mode
- single spot
- Date begin
- 2018-10-27
Versions
- Release date
- 2018-11-05 10:00:41 UTC+0000
- Version (Date)
- #1 (2018-11-05 10:00:41 UTC+0000, Updated: 2018-11-20 14:23:23 UTC+0000)