Spectrum

Ti K edge XAS transmission of Ti metallic reference foil at ambient conditions

Title
Ti K edge XAS transmission of Ti metallic reference foil at ambient conditions
DOI
10.26302/SSHADE/EXPERIMENT_DT_20180117_006
Data reference
Proux, Olivier (2004): Ti K edge XAS transmission of Ti metallic foil reference at ambient conditions. SSHADE/FAME (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_DT_20180117_006
Database
Experimentalists
Experiment type
laboratory measurement
Type
transmission
Intensity unit
AU
Instrument
X-ray Absorption Spectroscopy measured in transmission mode
Standard medium
unknown
Observation mode
spectrum
Spectral range type(s)
hard X
Valid spectral range(s)
Min - Max (eV) Sampling (eV) Resolution (eV) Position accuracy (eV) Absorption edge
#1 4851.0 - 5815.0 0.26 Ti (K: 4.9664 keV)
Comments
The resolution in the above table is the resolution given by the monochromator. The energy was calibrated on the spectrum itself: by definition, th first maximum of the derivative was set at 4966 eV.
Observation mode
single spot
Experiment
Ti K edge XAS transmission of Ti metallic foil reference at ambient conditions
Date begin
2004-11-07
Release date
2018-01-31 23:51:01+0000 UTC
Version (Date)
#1 (2018-01-31 23:51:01+0000 UTC)
History
Date Mode Version Status Comments
2018-01-17 17:06:02+0000 UTC first import #1 valid version First import
Analysis
raw averaged spectra
Quality flag
3