Spectrum

MIR absorbance spectrum of bulk LEW85311 CM chondrite in KBr pellet at T = 300°C

Title
MIR absorbance spectrum of bulk LEW85311 CM chondrite in KBr pellet at T = 300°C
DOI
10.26302/SSHADE/EXPERIMENT_LB_20170721_001
Data reference
Beck, Pierre; Garenne, Alexandre (2012): Mid-IR absorbance spectra of bulk CM chondrites in KBr pellets at ambient temperature, 150°C and 300°C. SSHADE/GhoSST (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_LB_20170721_001
Publications
Experiment type
laboratory measurement
Type
absorbance
Instrument
Brucker Vertex 70v – transmission Mid-IR
Standard medium
vacuum
Observation mode
spectrum
Spectral range type(s)
MIR
Valid spectral range(s)
Min - Max ($cm^{-1}$) Sampling ($cm^{-1}$) Resolution ($cm^{-1}$) Position accuracy ($cm^{-1}$) Absorption edge
#1 400.0 - 5000.0 1.9287 4.0 0.05
Scan number
64
Observation mode
single spot
Spots number
1
Resolutions
3.0 ${\pm}$ 1.0 ${\mu}m$
Comments
laser right in the center - spot of a few microns
Experiment
Mid-IR absorbance spectra of bulk CM chondrites in KBr pellets at ambient temperature, 150°C and 300°C
Date begin
2012-04-06
Release date
2018-01-31 23:51:01 UTC+0000
Version (Date)
#1 (2018-01-31 23:51:01 UTC+0000, Updated: 2021-01-15 07:28:52 UTC+0000)
History
Date Mode Version Status Comments
2017-07-28 12:50:48 UTC+0000 first import #1 valid version 2017-07-21: new MIR spectra
Analysis
raw calibrated transmission spectrum converted in absorbance
Quality flag
4
Validator(s)