Spectrum preview
Title
VNIR reflectance of thermonatrite 125-150 µm grain size at T = 258 K
Database
Experiment type
laboratory measurement
Spectrum type
reflectance factor
Version
#1 (2018-07-24 15:37:37 UTC+0000)
Instrument parameters
Instrument
SHINE Spectro-Gonio bidirectional reflection Vis-NIR
Spectral observation mode
spectrum
Valid spectral range(s)
0.5 - 0.7 ${\mu}m$ ; 0.7 - 1.6 ${\mu}m$ ; 1.6 - 3.0 ${\mu}m$ ; 3.0 - 3.98 ${\mu}m$
Observation geometry
bidirectional : i=15.0° ; e=0.0° ; az=0.0° ; ph=15.0°
Angle observation mode
fixed angles
Spatial observation mode
single spot
Sample preview
Name
thermonatrite powder (125-150µm grains)
Texture
loose granular
Thickness
5.0 $\pm$ 0.2 $mm$
Temperature
258.0 $\pm$ 1.0 $K$
Fluid
References
Data reference
DeAngelis, Simone; Carli, Cristian; Tosi, Federico; Beck, Pierre; Brissaud, Olivier; Schmitt, Bernard; Potin, Sandra (2016): VNIR reflectance spectra of Thermonatrite with 3 different grain sizes and at variable temperature (93-279 K). SSHADE/REFL_SLAB+CSS (OSUG Data Center). Dataset/Spectral Data. https://doi.org/10.26302/SSHADE/EXPERIMENT_CC_20180724_01